SMB Direct over RoCE Demo – Hosts & Switches Configuration Example


As mentioned in Where SMB Direct, RoCE, RDMA & DCB fit into the stack this post’s only function is to give you an overview of the configurations used in the demo blogs/videos. First we’ll configure one Windows Server 2012 R2 host. I hope it’s clear this needs to be done on ALL hosts involved. The NICs we’re configuring are the 2 RDMA capable 10GbE NICs we’ll use for CSV traffic, live migration and our simulated backup traffic. These are Mellanox ConnectX-3 RoCE cards we hook up to a DCB capable switch. The commands needed are below and the explanation is in the comments. Do note that the choice of the 2 policies, priorities and minimum bandwidths are for this demo. It will depend on your environment what’s needed.

#Install DCB on the hosts
Install-WindowsFeature Data-Center-Bridging
#Mellanox/Windows RoCE drivers don't support DCBx (yet?), disable it.
Set-NetQosDcbxSetting -Willing $False
#Make sure RDMA is enable on the NIC (should be by default)
Enable-NetAdapterRdma –Name RDMA-NIC1
Enable-NetAdapterRdma –Name RDMA-NIC2
#Start with a clean slate
Remove-NetQosTrafficClass -confirm:$False
Remove-NetQosPolicy -confirm:$False

#Tag the RDMA NIC with the VLAN chosen for PFC network
Set-NetAdapterAdvancedProperty -Name "RDMA-NIC-1" -RegistryKeyword "VlanID" -RegistryValue 110
Set-NetAdapterAdvancedProperty -Name "RDMA-NIC-2" -RegistryKeyword "VlanID" -RegistryValue 120

#SMB Direct traffic to port 445 is tagged with priority 4
New-NetQosPolicy "SMBDIRECT" -netDirectPortMatchCondition 445 -PriorityValue8021Action 4
#Anything else goes into the "default" bucket with priority tag 1 🙂
New-NetQosPolicy "DEFAULT" -default  -PriorityValue8021Action 1

#Enable PFC (lossless) on the priority of the SMB Direct traffic.
Enable-NetQosFlowControl -Priority 4
#Disable PFC on the other traffic (TCP/IP, we don't need that to be lossless)
Disable-NetQosFlowControl 0,1,2,3,5,6,7

#Enable QoS on the RDMA interface
Enable-NetAdapterQos -InterfaceAlias "RDMA-NIC1"
Enable-NetAdapterQos -InterfaceAlias "RDMA-NIC2"

#Set the minimum bandwidth for SMB Direct traffic to 90% (ETS, optional)
#No need to do this for the other priorities as all those not configured
#explicitly goes in to default with the remaining bandwith.
New-NetQoSTrafficClass "SMBDirect" -Priority 4 -Bandwidth 90 -Algorithm ETS

We also show you in general how to setup the switch. Don’t sweat the exact syntax and way of getting it done. It differs between switch vendors and models (we used DELL Force10 S4810 and PowerConnect 8100 / N4000 series switches), it’s all very alike and yet very specific. The important thing is that you see how what you do on the switches maps to what you did on the hosts.

!Disable 802.3x flow control (global pause)- doesn't mix with DCB/PFC
workinghardinit#configure
workinghardinit(conf)#interface range tengigabitethernet 0/0 -47 
workinghardinit(conf-if-range-te-0/0-47)#no flowcontrol rx on tx on
workinghardinit(conf-if-range-te-0/0-47)# exit
workinghardinit(conf)# interface range fortyGigE 0/48 , fortyGigE 0/52
workinghardinit(conf-if-range-fo-0/48-52)#no flowcontrol rx on tx off
workinghardinit(conf-if-range-fo-0/48-52)#exit

!Enable DCB & Configure VLANs
workinghardinit(conf)#service-class dynamic dot1p
workinghardinit(conf)#dcb enable
workinghardinit(conf)#exit
workinghardinit#copy running-config startup-config
workinghardinit#reload

!We use a <> VLAN per subnet
workinghardinit#configure
workinghardinit(conf)#interface vlan 110
workinghardinit (conf-if-vl-vlan-id*)#tagged tengigabitethernet 0/0-47
workinghardinit (conf-if-vl-vlan-id*)#tagged port-channel 3
workinghardinit(conf)#interface vlan 120
workinghardinit (conf-if-vl-vlan-id*)#tagged tengigabitethernet 0/0-47
workinghardinit (conf-if-vl-vlan-id*)#tagged port-channel 3
workinghardinit (conf-if-vl-vlan-id*)#exit


!Create & configure DCB Map Policy
workinghardinit(conf)#dcb-map SMBDIRECT
workinghardinit(conf-dcbmap-profile-name*)#priority-group 0 bandwidth 90 pfc on 
workinghardinit(conf-dcbmap-profile-name*)#priority-group 1 bandwidth 10 pfc off 
workinghardinit(conf-dcbmap-profile-name*)#priority-pgid 1 1 1 1 0 1 1 1
workinghardinit(conf-dcb-profile-name*)#exit 

!Apply DCB map to the switch ports & uplinks
workinghardinit(conf)#interface range ten 0/047
workinghardinit(conf-if-range-te-0/0-47)# dcb-map SMBDIRECT 
workinghardinit(conf-if-range-te-0/0-47)#exit
workinghardinit(conf)#interface range fortyGigE 0/48 , fortyGigE 0/52
workinghardinit(conf-if-range-fo-0/48,fo-0/52)# dcb-map SMBDIRECT
workinghardinit(conf-if-range-fo-0/48,fo-0/52)#exit
workinghardinit(conf)#exit
workinghardinit#copy running-config startup-config 

With the hosts and the switches configured we’re ready for the demos in the next two blog posts. We’ll show Priority Flow Control (PFC) and Enhanced Transmission Selection (ETS) in action with some tips on how to test this yourselves.

Advertisements

2 thoughts on “SMB Direct over RoCE Demo – Hosts & Switches Configuration Example

  1. Is there a typo on this line sir? :

    Disable-NetQosFlowControl 0,1,2,>>>4<<<,5,6,7

    I presume you meant to skip 4 in the sequence, not 3, as you enable PFC for class 4 using the command on the previous line.

    Have I got that right?

    Cheers!

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out /  Change )

Google+ photo

You are commenting using your Google+ account. Log Out /  Change )

Twitter picture

You are commenting using your Twitter account. Log Out /  Change )

Facebook photo

You are commenting using your Facebook account. Log Out /  Change )

Connecting to %s